{"id":1869,"date":"2020-03-24T10:55:14","date_gmt":"2020-03-24T10:55:14","guid":{"rendered":"https:\/\/seismicconsolidation.com\/?p=1869"},"modified":"2020-03-24T10:55:14","modified_gmt":"2020-03-24T10:55:14","slug":"flash-and-fire-point-test-for-asphalt-by-cleveland-open-cup-tester","status":"publish","type":"post","link":"https:\/\/seismicconsolidation.com\/flash-and-fire-point-test-for-asphalt-by-cleveland-open-cup-tester\/","title":{"rendered":"Flash and Fire Point Test for Asphalt by Cleveland Open Cup Tester"},"content":{"rendered":"

Job 6:<\/strong><\/p>\n

Flash and Fire Point Test for Asphalt by Cleveland Open Cup Tester<\/strong><\/p>\n

Code<\/strong>: ASTM: D 92-12<\/u><\/p>\n

S<\/u><\/strong>COPE & <\/u><\/strong>S<\/u><\/strong>IGNIFICANCE:<\/u><\/strong><\/p>\n

This test method describes the determination of the flash point and fire point of petroleum products by a manual Cleveland open cup apparatus<\/p>\n

This test method is applicable to all petroleum products with flash points above 79\u00b0C and below 400\u00b0C except fuel oils.<\/p>\n